+86 16692292870
CNC forging hammer issues and resolve
Problem: system fault of ejection
Reason: ①approach switch of hammer head is not work. ②magnetic valve of ejection part is blocked.
Resolve: ①right connection. Check whether approach switch loose or fault. ②Check, change.
please contact info@anyanghammer.com... More
The Safety Rules Of CNC Die Forging Hammer
The check before start hammer
1) Check the easy to loose bolts, if loose, tighten immediately.
2) Check the guide rails of hammer body, if don't have lubricating oil, start the lubrication pump to supply oil. If there is no oil in the lubrication pump, fill oil immediately.
3) Check the pressure accumulator with special tools (regular), if have leak, recharge immediately.
4) Check the pipes have oil leak or not, if any, solve it immediately.
5) Check hose whether damaged or not, if damaged, replace it immediately.
6) Check the fire fighting system that matching the hammer, if damaged, replace immediately.
7) Check the lighting throughout the production line, if damaged, replace it immediately.
8) Check the air pressure, if the pressure is low, adjust it immediately.
9) Check the cooling water get through or not, if not, open immediately.
10) Check the valve on the cooling oil road, all of them should be opened.
11) Ensure the work area that around the hammer is clean and tidy.... More
2001-2019 All Rights Reserved by Anyang Forging Press ( Group) Machinery Industry Co.,Ltd. Site Index | Product Index